Summary
Siemens Simcenter Femap and Nastran is affected by multiple file parsing vulnerabilities that could be triggered when the application reads files in NDB and XDB formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
The following versions of Siemens Simcenter Femap and Nastran are affected:
- Simcenter Femap vers:intdot/
- Simcenter Nastran vers:intdot/
| CVSS | Vendor | Equipment | Vulnerabilities |
|---|---|---|---|
| v3 7.8 | Siemens | Siemens Simcenter Femap and Nastran | Out-of-bounds Write, Out-of-bounds Read, Heap-based Buffer Overflow |
Background
- Critical Infrastructure Sectors: Critical Manufacturing
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Germany
Vulnerabilities
CVE-2026-23715
The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Affected Products
Siemens Simcenter Femap and Nastran
Siemens
Simcenter Femap, Simcenter Nastran
known_affected
Remediations
Mitigation
Do not open untrusted XDB files in affected applications
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/275652363/
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/289054037/
Relevant CWE: CWE-787 Out-of-bounds Write
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
CVE-2026-23716
The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Affected Products
Siemens Simcenter Femap and Nastran
Siemens
Simcenter Femap, Simcenter Nastran
known_affected
Remediations
Mitigation
Do not open untrusted XDB files in affected applications
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/275652363/
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/289054037/
Relevant CWE: CWE-125 Out-of-bounds Read
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
CVE-2026-23717
The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Affected Products
Siemens Simcenter Femap and Nastran
Siemens
Simcenter Femap, Simcenter Nastran
known_affected
Remediations
Mitigation
Do not open untrusted XDB files in affected applications
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/275652363/
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/289054037/
Relevant CWE: CWE-125 Out-of-bounds Read
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
CVE-2026-23718
The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Affected Products
Siemens Simcenter Femap and Nastran
Siemens
Simcenter Femap, Simcenter Nastran
known_affected
Remediations
Mitigation
Do not open untrusted XDB files in affected applications
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/275652363/
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/289054037/
Relevant CWE: CWE-125 Out-of-bounds Read
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
CVE-2026-23719
The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Affected Products
Siemens Simcenter Femap and Nastran
Siemens
Simcenter Femap, Simcenter Nastran
known_affected
Remediations
Mitigation
Do not open untrusted NDB files in affected applications
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/275652363/
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/289054037/
Relevant CWE: CWE-122 Heap-based Buffer Overflow
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
CVE-2026-23720
The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Affected Products
Siemens Simcenter Femap and Nastran
Siemens
Simcenter Femap, Simcenter Nastran
known_affected
Remediations
Mitigation
Do not open untrusted NDB files in affected applications
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/275652363/
Vendor fix
Update to V2512 or later version
https://support.sw.siemens.com/product/289054037/
Relevant CWE: CWE-125 Out-of-bounds Read
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 7.8 | HIGH | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Acknowledgments
- Siemens ProductCERT reported these vulnerabilities to CISA.
- Michael Heinzl reported these vulnerabilities Siemens.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens ProductCERT SSA-965753 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
- Initial Release Date: 2026-02-10
| Date | Revision | Summary |
|---|---|---|
| 2026-02-10 | 1 | Publication Date |
| 2026-02-17 | 2 | Initial CISA Republication of Siemens ProductCERT SSA-965753 advisory |